EP35-I / EP355-I - Digital Display

EP35-I / EP355-I - Digital Display

Zum Konfigurieren dieses Artikels benutzen Sie bitte den Bestellschlüssel:

Any questions?

Christian_Willmann

Your Contact

Christian Willmann
c.willmann@willtec.de
+49 (0)7665 - 93465-17


 

Download brochure 

  • EP35-I
  • Multi-function device with operating modes such as tachometer, counter, cycle time... more
Product information "EP35-I / EP355-I - Digital Display"

 

• Multi-function device with operating modes such as tachometer, counter, cycle time display

• Position display, timer for running times, stop watch or process display

• Universal inputs (HTL / RS422) for encoders / sensors with NPN / PNP / NAMUR characteristics

• Bright and high-contrast display with event-dependent color variants

• Emulation of a 7-segment display inclusively icons and units

• Intuitive and simple parameterization through plain text and touchscreen

• Auxiliary voltage output 5/24 VDC for encoder supply

• Input frequency up to 1 MHz

• Linearization with 24 control points

• Numerous functions such as scaling, filters, start-up override

• Standard installation housing with 96 x 48 mm and IP65 protection

 

 

Related links to "EP35-I / EP355-I - Digital Display"
Technische Daten anfordern ...Technische Daten anfordern ...
Technical data "EP35-I / EP355-I - Digital Display"

 

Mechanical Data

Dimensions

            Housing

            Cut out

 

96 x 48 x 116 mm

91 x 43 mm

Material

ABS, UL 94 V-0

Weight

approx. 200 g

Display

LCD (backlight)

Display range

8 digits plus sign (-99999999 … 99999999)

Digit height

13 mm

Color

red / green / yellow (switchable)

Operation

resistive touchscreen

Serial interface

            Format (option AO / CO)

            Format (option AR / CR)

            Baud rate

 

RS232

RS485

9600, 19200 or 38400 Baud

 

 

Storage temperature

-25 °C … +70 °C

Operation temperature

-20 °C … +60 °C

Conformity and standards

EMV 2014/30/EU:

 

NS 2014/35/EU:

(only for option AC und RL)

 

RoHS (Ⅱ) 2011/65/EU

RoHS (Ⅲ) 2015/863:

 

EN 61326-1

EN 55011 / CISPR11 class A

 

EN 61010-1

 

 

EN IEC 63000

Protection class

            front

            rear

 

IP65

IP20

 

Electrical Data

Power supply DC

            Input voltage

            Protection circuit

            Consumption

            Fuse protection

 

18 … 30 VDC

reverse polarity protection

approx.100 mA (unloaded)

extern T 0,5 A

Power supply AC

            Input voltage

            Protection circuit

            Fuse protection

(Option AC)

115 … 230 VAC, 50 … 60 Hz

approx. 3 VA (unloaded)

extern: T 0,1 A

Encoder supply

            DC version

            AC version

(EP35-I)

24 VDC (approx. 1 V lower than the power supply voltage), < 250 mA

24 VDC (±15%), (<150 mA bis 45°C / 80 mA ab 45°C)

Encoder supply

            DC version

 

            AC version

(EP355-I)

24 VDC approx. 1 V lower than the power supply voltage), < 250 mA or 5 VDC (±15%), < 250 mA

24 VDC (±15%), (<150 mA bis 45°C / 80 mA ab 45°C)

or 5 VDC (±15%), < 250 mA

Incremental inputs

            Number of tracks

            Configuration

            Format

            Frequency

            Load

(EP35-I)

2 (A, B)

PNP-; NPN-, Namur or Tri-State

HTL (Low 0 … 3 V, High 9 … 30 V)

< 250 kHz

max. 6 mA / Ri > 5 kΩ / 470 pF

Incremental inputs

            Number of tracks

            Configuration

            RS422

            HTL differential

            HTL PNP / NPN

            Load

(EP355-I)

2 A, , B

RS422, HTL differential, HTL PNP or HTL NPN

max. 1 MHz (RS422 differential > 0,5 V)

< 500 kHz (HTL differential signal > 2 V)

< 250 kHz (Low 0 … 3 V, High 9 … 30 V)

max. 2 mA / Ri > 10 kΩ / 47 pF

Control inputs

            Number of inputs

            Format

            Frequency

            Load

 

3

HTL, PNP (Low 0 … 3 V, High 9 … 30 V)

max. 10 kHz

max. 2 mA / Ri > 15 kΩ / 470 pF

Analog outputs

            Configuration

            Voltage output

            Current output

            Resolution

            Accuracy

            Reaction time

(Option AO / AR)

Current or voltage output

-10 … +10 V (<2 mA)

0/4 … 20 mA (burden <270 Ω)

16 Bit ± 0,1 % 0°C … +45°C

± 0,15 % -20°C … 0°C und +45°C…+60°C

< 150 ms

Control outputs

            Number of outputs

            Format / level

            Current output

            Reaction time

(Option AO / AR / CO / CR)

4

5 … 30 V (according to output voltage at OM+), PNP

max. 200 mA

< 1 ms

Relay outputs

            Number of outputs

            Configuration

            AC-Switching capacity

            DC-Switching capacity

            Reaction time

(Option RL)

2

potential free changeovers

max. 250 VAC / 3 A / 750 VA

max. 150 VDC / 2 A / 50 W

< 20 ms

 

 

Zeichnung anfordern ...Zeichnung anfordern ...
Drawing "EP35-I / EP355-I - Digital Display"
Datenblatt anfordern ...Datenblatt anfordern ...
Get Datasheet files for "EP35-I / EP355-I - Digital Display"
CAD Daten anfordern ...CAD Daten anfordern ...
Get CAD files for "EP35-I / EP355-I - Digital Display"

 

CAD-Files: Please request

 

 

Bestellschlüssel anfordern ...Bestellschlüssel anfordern ...
Ordercode "EP35-I / EP355-I - Digital Display"
Viewed
Top