Magnetic sensor MIP2
Pole Pitch | 2 mm |
Resolution | 100, 50, 10, 5, 1, 0.5, 0.2 µm |
Accuracy | ± 8 µm |
Measuring length | depending on magnetic tape |
Interface | Line Driver, Push-Pull |
Zum Konfigurieren dieses Artikels benutzen Sie bitte den Bestellschlüssel:
Any questions?
Your Contact
Christian Willmann
c.willmann@willtec.de
+49 (0)7665 - 93465-17
Download brochure
- Order number: MIP2
- Magnetic sensor for linear and angular contactless reading
- Very small size 36 x 11 x 13,5 mm to allow installation in narrow spaces
- Housing made of die-cast metallic material
- Resolutions up to 0.2 μm
- Status indication through LED RGBW
- Flexible cable for axial or radial connection
- Easy and fast mounting of the entire measuring system, with wide alignment tolerances
- Distance sensor/magnetic scale up to 0.3 mm
- Speed up to 47 m/s
- IP-Rating IP67
- Option: cleaning wipers to remove dirt deposits from the magnetic scale
Technical data
Pole pitch |
2+2 mm |
||||||
Reference indexes |
C = constant step (every 4 mm) R = positioned on the magnetic scale |
||||||
Resolution [µm] |
100 |
50 |
10 |
5 |
1 |
0.5 |
0.2 |
Accuracy grade |
± 8 μm 1) |
||||||
Interpolation error (SDE) |
± 1 μm 2) |
||||||
Unidirectional repeatability |
± 0.5 μm 2) |
||||||
Hysteresis |
2 μm 2) |
||||||
A, B and I0 output signals |
Line Driver / Push-Pull |
||||||
Vibration resistance (EN 60068-2-6) |
300 m/s2 [55 … 2000 Hz] |
||||||
Shock resistance (EN 60068-2-27) |
1000 m/s2 [11 ms] |
||||||
Protection class (EN 60529) |
IP 67 |
||||||
Operating temperature |
-20 °C … 75 °C |
||||||
Storage temperature |
-40 °C … 80 °C |
||||||
Relative humidity |
100% |
||||||
Power supply |
5 to 24 VDC ±10% 3) |
||||||
Current consumption without load |
40 mAMAX |
||||||
Current consumption with load |
100 mAMAX (with 5 V and R = 120 Ω) 80 mAMAX (with 24 V and R = 1.2 kΩ) |
||||||
Electrical connections |
8-wire connecting cable, open cable end (standard) M12-connector (plug); 8-pin (optional) Other connections on request |
||||||
Electrical protections |
inversion of polarity and short circuits |
||||||
Weight |
20 g |
1) The declared accuracy grade of ± X μm is referred to a measuring length of 1 m.
2) The error declared is subject to the respect of the alignment tolerances.
3) Voltages higher than 27 VDC will damage the sensor.