Glasmaßstab - absolut - GVS608T
Zum Konfigurieren dieses Artikels benutzen Sie bitte den Bestellschlüssel:
Any questions?
Your contact
Christian Willmann
c.willmann@willtec.de
+49 (0)7665 - 93465-17
Download brochure
- Order number: GVS608T
Direct reading of the absolute position
Suitable for CNC machines
Resolution up to 0.01... more
Product information "Glasmaßstab - absolut - GVS608T"
- Direct reading of the absolute position
- Suitable for CNC machines
- Resolution up to 0.01 μm, depending on the version
- Accuracy ± 2 μm
- Max. Travel speed 120 m / min
- Pole width 20 μm
- With sealing air on request
- With serial interfaces: SSI / BISS
Related links to "Glasmaßstab - absolut - GVS608T"
Technische Daten anfordern ...Technische Daten anfordern ...
Technical data "Glasmaßstab - absolut - GVS608T"
Feature | Technical Data |
Measuring support | glass scale |
Grating pitch | 20 μm |
Linear thermal expansion coefficient | 8 x 10-6 °C-1 |
Incremental signal (optional) | sine wave 1 Vpp (optional) |
Resolution 1 Vpp | up to 0.1 μm* |
Serial interface | SSI - BiSS C (unidirectional) |
Resolution absolute measure | 1 - 0.1 - 0.01 μm ** |
Accuracy grade | ± 5 μm *** standard version ± 3 μm *** high-accuracy version, ± 2 μm for measuring length ≤720 mm |
Measuring length ML in mm | 170, 220, 270, 320, 370, 420, 470, 520, 570, 620, 720, 770, 820, 920, 1020, 1140, 1240, 1340, 1440, 1540, 1640, 1740, 1840, 2040, 2240, 2440, 2640, 2840, 3040, 3240 (Max. length) |
Max. traversing speed | 120 m/min |
Max. acceleration | 30 m/s2 |
Required moving force | ≤ 2.5 N |
Vibration resistance (EN 60068-2-6) | 100 m/s2 [55 ÷ 2000 Hz] |
Shock resistance (EN 60068-2-27) | 150 m/s2 [11 ms] |
Protection class (EN 60529) | IP 54 standard IP 64 pressurized |
Operating temperature | 0 °C ÷ 50 °C |
Storage temperature | -20 °C ÷ 70 °C |
Relative humidity | 20% ÷ 80% (not condensed) |
Reading block sliding | by ball bearings |
Power supply | 5 Vdc ± 10% |
Current consumption | 280 mAMAX (with R = 120 Ω) |
Max. cable length | 20 m **** |
Electrical connections | see related table |
Connector | inside the transducer |
Electrical protections | inversion of polarity and short circuits |
Weight | 435 g + 1.290 g/m |
* Depending on CNC division factor.
** The resolution of 0.01 μm is available only with BiSS protocol.
*** The declared accuracy grade of ± X μm is referred to a measuring length of 1 m.
**** Ensuring a minimum power supply voltage of 5 V to the transducer, the maximum length can be extended to 50 m.
Zeichnung anfordern ...Zeichnung anfordern ...
Drawing "Glasmaßstab - absolut - GVS608T"
Datenblatt anfordern ...Datenblatt anfordern ...
Get Datasheet files for "Glasmaßstab - absolut - GVS608T"
CAD Daten anfordern ...CAD Daten anfordern ...
Get CAD files for "Glasmaßstab - absolut - GVS608T"
CAD-Files: Please request.
Bestellschlüssel anfordern ...Bestellschlüssel anfordern ...
Ordercode "Glasmaßstab - absolut - GVS608T"
Passendes ZubehörPassendes Zubehör anfragen ...
Accessories "Glasmaßstab - absolut - GVS608T"
Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
Allow all cookies
CSRF token
Cookie preferences
Currency change
Customer-specific caching
Decline all cookies
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Google Analytics
Track device being used
Viewed