- Order number: GVS206S
Optical scale with direct reading of the absolute position
Characteristics:... more
Product information "Glasmaßstab - absolut - GVS206S"
Optical scale with direct reading of the absolute position
Characteristics:
- Particularly suitable for synchronized press brakes
- High-speed serial interface
- Reader head guided by a self-aligned and self-cleaning
- Sliding carriage with spring system
- Resolutions up to 0.1 μm; accuracy grade up to &plusm; 1 μm
- Adjustable cable output
- Symmetric mechanical mounting
- Various possibilities of application, with double-effect
- Joint or steel wire
- Option: 1 Vpp analog signal
Related links to "Glasmaßstab - absolut - GVS206S"
Technische Daten anfordern ...Technische Daten anfordern ...
Technical data "Glasmaßstab - absolut - GVS206S"
Feature | Technical Data |
Measuring support | stainless steel grating |
Grating pitch | 204.8 μm |
Linear thermal expansion coefficient | 10.6 x 10-6 °C-1 |
Incremental signal (optional) | TTL Line Driver |
Resolution Line Driver | 5 μm - 1 μm |
Serial interface | SSI - BiSS C (unidirectional) |
Resolution absolute measure | 1 μm - 0.1 μm |
Accuracy grade | ± 2,5 μm * standard version ± 1 μm * high-accuracy version |
Measuring length ML in mm | 170, 220, 270, 320, 370, 420, 470, 520, 570, 620, 720, ... mm max. 6000 mm in modular version |
Max. traversing speed | 60 m/min |
Max. acceleration | 30 m/s2 |
Required moving force | ≤ 1.5 N |
Vibration resistance (EN 60068-2-6) | 100 m/s2 [55 ÷ 2000 Hz] |
Shock resistance (EN 60068-2-27) | 150 m/s2 [11 ms] |
Protection class (EN 60529) Operating temperature | IP 54 standard IP 64 pressurized |
operating temperature | 0 °C ÷ 50 °C |
Storage temperature | -20 °C ÷ 80 °C |
Relative humidity | 20% ÷ 80% (not condensed) |
Reading block sliding | without contact |
Power supply | 5 Vdc ± 5% 200 mAMAX or 10 ÷ 28 Vdc ± 5% |
Current consumption (with R = 120 Ω) | 200 mAMAX 140 mATYP 5 Vdc 50 mAMAX 30 mATYP 10 ÷ 28 Vdc |
Max. cable length | 20 m ** |
Electrical connections | see related table |
Electrical protections | inversion of polarity and short circuits |
Weight | 850 g + 1.800 g/m |
* The declared accuracy grade of ± X μm is referred to a measuring length of 1 m.
** Ensuring the required power supply voltage to the transducer, the maximum cable length can be extended to 50 m.
Zeichnung anfordern ...Zeichnung anfordern ...
Drawing "Glasmaßstab - absolut - GVS206S"
Datenblatt anfordern ...Datenblatt anfordern ...
Get Datasheet files for "Glasmaßstab - absolut - GVS206S"
CAD Daten anfordern ...CAD Daten anfordern ...
Get CAD files for "Glasmaßstab - absolut - GVS206S"
CAD-Files: Please request.
Bestellschlüssel anfordern ...Bestellschlüssel anfordern ...
Ordercode "Glasmaßstab - absolut - GVS206S"
Passendes ZubehörPassendes Zubehör anfragen ...
Accessories "Glasmaßstab - absolut - GVS206S"
Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
Allow all cookies
CSRF token
Cookie preferences
Currency change
Customer-specific caching
Decline all cookies
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Google Analytics
Track device being used
Viewed