  • GVS202S
Incremental optical scale with stainless steel measuring support particularly suitable for... more
Product information "Optical Scale - Incremental GVS202S"
Incremental optical scale with stainless steel measuring support particularly suitable for synchronized press brakes
 
Characteristics:
 
 
  • Reader head guided by a self-aligned and self-cleaning sliding carriage with spring system
  • Resolutions up to 0.1 μm; accuracy grade up to ± 1 μm
  • Adjustable cable output
  • Reference indexes at coded distance or selectable every 10 mm along the entire measuring length, with Zero Magneto Set device
  • The adjustable cable output and the selectable zero references make the scale SYMMETRIC and applicable, in the same version, to both columns of the press brake
  • Various possibilities of application, with double-effect joint or steel wire
  • Option: safety limit switches, positionable at both ends
 
 
Related links to "Optical Scale - Incremental GVS202S"
Technische Daten anfordern ...Technische Daten anfordern ...
Technical data "Optical Scale - Incremental GVS202S"
Properties Technical data
Measuring support stainless steel
Grating pitch 250 μm
Thermal expansion coefficient 10.6 x 10⁻⁶ °C
Reference indexes (I) E = selectable (every 10 mm) 
Resolution 10 - 5 - 1 - 0.5 - 0.1 μm
Accuracy grade ± 2.5 μm standard version
± 1 μm high-accuracy version
Measuring length ML in mm 170, 220, 270, 320, 370, 420, … mm
max. 30000 mm in modular version
Max. traversing speed up to 120 m/min *
Max. acceleration 30 m/s²
Required moving force < 1.5 N
Vibration resistance (EN 60068-2-6) 100 m/s²            [55-2000 Hz]
Shock resistance (EN 60068-2-27) 150 m/s²            [11 ms]
Protection class (EN 60529) IP 54 standard            IP 64 pressurized **
Operating temperature 0 °C - 50 °C (-10 °C - 60 °C on request)
Storage temperature -20 °C - 80 °C
Relative humidity 20% - 80% (not condensed)
Carriage sliding without contact
Power supply 5 Vdc ± 5% or 10 - 28 Vdc ± 5%
Current consumption 140 mAMAX (with R = 120 Ω) 5 Vdc
100 mAMAX (with R = 1200 Ω) 10 - 28 Vdc
A, B and I₀ output signals LINE DRIVER
PUSH-PULL
Max. cable length 25 m ***
Electrical connections see datasheet
Electrical protections inversion of polarity and short circuits
Weight 850 g + 1800 g/m

 

* With a 0.5 µm resolution, the maximum traversing speed becomes 60 m/min.
With a 0.1 µm resolution, the maximum traversing speed becomes 40 m/min
** Pressurization set up on request.
*** Ensuring the required power supply voltage to the transducer, the maximum cable length can be extended to 100 m.

 

Zeichnung anfordern ...Zeichnung anfordern ...
Drawing "Optical Scale - Incremental GVS202S"
Datenblatt anfordern ...Datenblatt anfordern ...
Get Datasheet files for "Optical Scale - Incremental GVS202S"
CAD Daten anfordern ...CAD Daten anfordern ...
Get CAD files for "Optical Scale - Incremental GVS202S"
Bestellschlüssel anfordern ...Bestellschlüssel anfordern ...
Ordercode "Optical Scale - Incremental GVS202S"
Viewed
Top