Optical Scale - Incremental GVS600
Zum Konfigurieren dieses Artikels benutzen Sie bitte den Bestellschlüssel:
Any questions?
Your Contact
Christian Willmann
c.willmann@willtec.de
+49 (0)7665 - 93465-17
Download brochure
- Order number: GVS600
Optical scale with glass measuring support (grating pitch 20 μm). Particularly suitable for CNC... more
Product information "Optical Scale - Incremental GVS600"
Optical scale with glass measuring support (grating pitch 20 μm). Particularly suitable for CNC machines.
Characteristics:
- Innovative device inside the scale for the disposal of liquids coming from inefficient filtering systems.
- Adjustable connecting cable output.
- Reference indexes at coded distance, or at constant step, with predetermined or selectable positions.
- Small size, to allow installation in narrow spaces.
- Available with 1 Vpp and Line Driver output
Related links to "Optical Scale - Incremental GVS600"
Technische Daten anfordern ...Technische Daten anfordern ...
Technical data "Optical Scale - Incremental GVS600"
Properties | Technical data |
Measuring support | glass scale |
Grating pitch | 20 µm |
Thermal expansion coefficient | 8 x 10⁻⁶ °C⁻ |
Reference indexes (I₀) | C = coded distance P = constant step (every 40 mm) E = selectable (every 20 mm) |
Resolution GVS600T | 5 - 1 - 0.5 - 0.1 - 0.05 - 0.01 µm |
Resolution GVS600V | up to 0.01 µm |
Accuracy grade |
±5 µm standard* ±3 µm high-accuracy* (±2 µm at ML up to 720 mm) |
Measuring length ML in mm | 70, 120, 170, 220, 270, 320, … 3240 mm |
Max. traversing speed | 120 m/min** |
Max. acceleration | 30 m/s² |
Required moving force | < 2.5 N |
Vibration resistance (EN 60068-2-6) | 100 m/s² [55-2000 Hz] |
Shock resistance (EN 60068-2-27) | 150 m/s² [11 ms] |
Protection class (EN 60529) | IP 54 standard IP 64 pressurized |
Operating temperature | 0 °C - 50 °C |
Storage temperature | -20 °C - 70 °C |
Relative humidity | 20% - 80% (not condensed) |
Carriage sliding | by ball bearings |
Power supply | 5 Vdc ± 5% |
Current consumption GVS600T | 140 mAMAX (with R = 120 Ω) |
Current consumption GVS600V | 120 mAMAX (with R = 120 Ω) |
A, B and I₀ output signals | LINE DRIVER 1 VPP, 20 µm PUSH-PULL |
Max. cable length | 100 m (LINE DRIVER) 80 m (1 VPP) 50 m (PUSH-PULL) |
Electrical connections | see datasheet |
Electrical protections | inversion of polarity and short circuits |
Weight | 435 g + 1290 g/m |
*The declared accuracy grade is referred to a measuring length of 1 m.
Zeichnung anfordern ...Zeichnung anfordern ...
Drawing "Optical Scale - Incremental GVS600"
Datenblatt anfordern ...Datenblatt anfordern ...
Get Datasheet files for "Optical Scale - Incremental GVS600"
CAD Daten anfordern ...CAD Daten anfordern ...
Get CAD files for "Optical Scale - Incremental GVS600"
Bestellschlüssel anfordern ...Bestellschlüssel anfordern ...
Ordercode "Optical Scale - Incremental GVS600"
Output signal voltage:
Output signal current:
Passendes ZubehörPassendes Zubehör anfragen ...
Accessories "Optical Scale - Incremental GVS600"
Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
Allow all cookies
CSRF token
Cookie preferences
Currency change
Customer-specific caching
Decline all cookies
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Google Analytics
Track device being used
Viewed